  • ELG-150-48 Mean Well LED Power Supply

Model No. - ELG-150 Series

Max Output Wattage (W) - 150 Watts

Output Voltage (VDC) - 12, 24, 36, 42, 48, 54  Volts

Model No. ELG-150-12
ELG-150-24 ELG-150-36
ELG-150-42
ELG-150-48 ELG-150-54
Output:  DC Voltage 12V
24V 36V 42V 48V 54V
Constant Current Region 6~12V 12~24V 18~36V 21~42V 24~48V 27~54V
Rated Current 10A 6.25A 4.17A 3.57A 3.13A 2.8A
Rated Power    200VAC~305VAC
120W 150W 150.1W 150W 150.2W 151.2W
100VAC~180VAC
84W 105W 105W 105W 105W 105W
Ripple & Noise (max.) 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 300mVp-p
Voltage ADJ. Range  Adjustable for A-Type only (via built-in potentiometer)
10.8 ~ 13.2V
21.6 ~ 26.4V 32.4 ~ 39.6V
37.8 ~ 46.2V
43.2 ~ 52.8V
49 ~ 58V
Current Adj. Range Adjustable for A-Type only (via built-in potentiometer)
5 ~ 10A
3.2 ~ 6.25A 2.1 ~ 4.17A
1.8 ~ 3.57A
1.56 ~ 3.13A
1.4 ~ 2.8A
Voltage Tolerance ±3.0% ±3.0% ±2.5% ±2.5% ±2.0% ±2.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5%
Auxiliary DC Output Nominal 15V(deviation 11.5~15.5V)@0.4A for BE-Type only
Setup, Rise Time 1600ms, 80ms/115VAC          500ms, 100ms/230VAC
Hold up Time 10ms/ 115VAC, 230VAC
Input: Voltage Range

100 ~ 305VAC 142 ~ 431VDC

(Please refer to "STATIC CHARACTERISTIC" section)

Frequency Range

47~63Hz
Power Factor (Typ.)

PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

Total Harmonic Distortion

THD< 20%(@load≧50%/115VC; @load≧60%/230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

Efficiency (Typ.) 88% 89% 90% 90% 90% 91%
AC Current (Typ.) 1.7A / 115VAC 0.9A / 230VAC 0.7A/277VAC
Inrush Current (Typ.) COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
Leakage Current <0.75mA / 277VAC
Protection: Over Current 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Short Circuit Protection Hiccup mode, recovers automatically after fault condition is removed.
Over Voltage 14 ~18V 28 ~ 34V 41 ~ 48V 47 ~ 54V 54 ~ 62V 59 ~ 68V
Shut down output voltage, re-power on to recover
Over Temperature Shut down output voltage, re-power on to recover
Environment: Working Temp. Tcase=-40 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Max. Case Temp Tcase=+90℃
Working Humidity 20 ~ 95% RH non-condensing
Storage Temp., Humidity -40 ~ +80°C, 10 ~ 95% RH
Temp. Coefficient ±0.03%/°C (0 ~ 60°C)
Vibration 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety & EMC Safety Standards UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1, GB19510.14; IP65 or IP67 approved
Dali Standards Compliance to IEC62386-101, 102, 207 for DA-Type only
Withstand Voltage I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC Emission Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3; GB17743, GB17625.1
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
Others: MTBF 899.8K hrs min. Telcordia SR-332 (Bellcore) 313.66Khrs min. MIL-HDBK-217F (25℃)
Dimension 219*63*35.5mm (L*W*H)
Packing 0.95Kg ; 16pcs/16.0kg/0.77CUFT
Electrical Specifications
Dimensions 219*63*35.5mm (L*W*H)
Input Voltage NA
Model Type Primary model - Type
Number of Outputs 1
Output Voltage 48V
PDF Specs View Spec Sheet
Wattage 150
General
Dimmable Dimming
Industry Aliases new

ELG-150-48 Mean Well LED Power Supply

  • Brand: Mean Well
  • Product Code: ELG-150-48
  • Availability: Call for Availability
  • $47.21