web statistics
  • ELG-240-24 Mean Well LED Power Supply

Model No. - ELG-240 Series

Max Output Wattage (W) - 240 Watts

Output Voltage (VDC) - 24, 36, 42, 48, 54  Volts

Model No. ELG-240-24 ELG-240-36
ELG-240-42
ELG-240-48 ELG-240-54
Output:  DC Voltage 24V 36V 42V 48V 54V
Constant Current Region 12~24V 18~36V 21~42V 24~48V 27~54V
Rated Current 10A 6.66A 5.71A 5A 4.45A
Rated Power    200VAC~305VAC
240W 239.76W 239.82W 240W 240.3W
100VAC~180VAC
180W 180W 179.76W 180W 180.36W
Ripple & Noise (max.) 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p
Voltage ADJ. Range  Adjustable for A-Type only (via built-in potentiometer)
22.4 ~ 25.6V 33.5 ~ 38.5V
39 ~ 45V
44.8 ~ 51.2V
50 ~ 57V
Current Adj. Range Adjustable for A-Type only (via built-in potentiometer)
5 ~ 10A 3.33 ~ 6.66A
2.86 ~ 5.71A
2.5 ~ 5A
2.23 ~ 4.45A
Voltage Tolerance ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
Hold up Time 10ms/ 230VAC 10ms/ 115VAC
Input: Voltage Range

100 ~ 305VAC 142 ~ 431VDC

(Please refer to "STATIC CHARACTERISTIC" section)

Frequency Range

47~63Hz
Power Factor (Typ.)

PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

Total Harmonic Distortion

THD< 20%(@load≧50%/115VC; @load≧60%/230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

Efficiency (Typ.) 92% 92% 92.5% 93% 93%
AC Current (Typ.) 2.2A / 115VAC 1.5A / 230VAC 1.2A/277VAC
Inrush Current (Typ.) COLD START 60A(twidth=510μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
Leakage Current <0.75mA / 277VAC

No Load/ Standby Power Consumption

No load power consumption <0.5W for Blank / A / Dx / D-Type

Standby power consumption <0.5W for B / DA-Type

Protection: Over Current 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Short Circuit Protection Hiccup mode, recovers automatically after fault condition is removed.
Over Voltage 27 ~ 34V 42 ~ 49V 47 ~ 54V 54 ~ 63V 60 ~ 67V
Shut down output voltage, re-power on to recover
Over Temperature Shut down output voltage, re-power on to recover
Environment: Working Temp. Tcase=-40 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Max. Case Temp Tcase=+90℃
Working Humidity 20 ~ 95% RH non-condensing
Storage Temp., Humidity -40 ~ +90°C, 10 ~ 95% RH
Temp. Coefficient ±0.03%/°C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety & EMC Safety Standards UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1, GB19510.14; IP65 or IP67 approved
Dali Standards Compliance to IEC62386-101, 102, 207 for DA-Type only
Withstand Voltage I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC Emission Compliance to EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3; GB17743, GB17625.1
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
Others: MTBF 826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25℃)
Dimension 244*71*37.5mm (L*W*H)
Packing 1.22Kg; 12pcs / 15.2Kg / 0.72CUFT
Electrical Specifications
Dimensions 244*71*37.5mm (L*W*H)
Input Voltage NA
Model Type Primary model - Type
Number of Outputs 1
Output Voltage 24V
PDF Specs View Spec Sheet
Wattage 104
General
Dimmable Dimming
Industry Aliases new

ELG-240-24 Mean Well LED Power Supply

  • Brand: Mean Well
  • Product Code: ELG-240-24
  • Availability: Call for Availability
  • $47.70

  • Ex Tax: $47.70

Available Options