Mean Well Authorized Distributor since 1997
Model No.- LPF-40D-20
Max Output Wattage (W) - 40 Watts
Output Voltage (VDC) - 20 Volts
Model No. | LPF-40D-12 | LPF-40D-15 | LPF-40D-20 | LPF-40D-24 | LPF-40D-30 | LPF-40D-36 | LPF-40D-42 | LPF-40D-48 | LPF-40D-54 | |
Outpout: | DC Voltage | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
Constant Current Region | 7.2~12V | 9~15V | 12~20V | 14.4~24V | 18~30V | 21.6~36V | 25.2~42V | 28.8~48V | 32.4~54V | |
Rated Current | 3.34A | 2.67A | 2A | 1.67A | 1.34A | 1.12A | 0.96A | 0.84A | 0.76A | |
Rated Power | 40.08W | 40.08W | 40W | 40.08W | 40.2W | 40.32W | 40.32W | 40.32W | 41.04W | |
Ripple & Noise (max.) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
Voltage Tolerance | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±2.0 | ±1.5 | ±1.0 | ±0.5 | ±0.5 | ±0.5 | ±0.5 | ±0.5 | ±0.5 | |
Setup, Rise Time | 1000ms, 80ms/115VAC at full load - - - 1000ms, 80ms/320VAC | |||||||||
Hold up Time | 16ms/230VAC - - - 16ms/115VAC at full load | |||||||||
input: | Voltage Range | 90 ~ 305VAC | 127 ~ 431VDC | ||||||||
Frequency Range |
47~63Hz | |||||||||
Power Factor (Typ.) | PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||||||
Efficiency (Typ.) | 84% | 85% | 86% | 87% | 88% | 88% | 84.5% | 89% | 89% | |
AC Current (Typ) | 0.6A/115VAC --- 0.3A/230VAC --- 0.25A/277VAC | |||||||||
Inrush Current (Typ.) | COLD START 50A (twidth=210µS measured at 50% lpeak) at 230VAC | |||||||||
Leakage Current | <0.75mA / 240VAC | |||||||||
Protection: | Over Current | 95 ~ 108% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
Short Circuit Protection | Hiccup mode, recovers automatically after fault condition is removed. | |||||||||
Over Voltage | 15~17V | 17.5~21V | 23~27V | 28~35V | 34~40V | 41~49V | 46~54V | 54~63V | 59~66V | |
Protection type: Shut down and latch off o/p voltage, re-power on to recover | ||||||||||
Over Temperature | 90°C±10°C (RTH2) | |||||||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||
Environment: | Working Temp. | -35 ~ +70°C (Refer to "Derating Curve") | ||||||||
Working Humidity | 20 ~ 95% RH non-condensing | |||||||||
Storage Temp., Humidity | -40 ~ +80°C, 10 ~ 95% RH | |||||||||
Temp. Coefficient | ±0.03%/°C (0 ~ 50°C) | |||||||||
Vibration | 10 ~ 500Hz, 2G 12min. / 1cycle, period for 72min. each along X, Y, Z axes | |||||||||
Safety & EMC | Safety Standards | UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, EN62384, J61347-1, J61347-2-13 approved, IP67(optional), ; Design refer to UL60950-1, TUV EN60950-1 | ||||||||
Withstand Voltage | I/P - O/P : 3.75KVAC | |||||||||
Isolation Resistance | I/P - O/P : 100M Ohms / 500VDC / 25°C / 70% RH | |||||||||
EMC Emission | Compliance to EN55015, En61000-3-2 Class C ( ≥50% load) ; EN61000-3-3 | |||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A | |||||||||
Others: | MTBF | 394.9Khrs min. MIL-HDBK-217F (25°C) | ||||||||
Dimension | 162.5 x 43 x 32mm (LxWxH) | |||||||||
Packing | 0.45Kg; 32pcs / 15.4Kg / 0.93CUFT |
Electrical Specifications | |
Dimensions | 162.5 x 43.5 x 32 mm |
Input Voltage | 90~305VAC |
Number of Outputs | 1 |
Output Voltage | 20V |
PDF Specs | View Spec Sheet |
Wattage | 40 |
General | |
Industry Aliases | new |
LPF-40D-20 Mean Well LED Power Supply
- Brand: Mean Well
- Product Code: LPF-40D-20
- Availability: Call for Availability
-
$27.00
- Ex Tax: $27.00