web statistics
  • HEP-600-12


Mean Well Authorized Distributor since 1997

Model No. HEP-600 Series

Max Output Wattage (W) - 600 Watts

Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts

Model No.

HEP-600-12

HEP-600-15

HEP-600-20

HEP-600-24

HEP-600-30

HEP-600-36

HEP-600-42

HEP-600-48

HEP-600-54

Output: 

DC Voltage

12V

15V

20V

24V

30V

36V

42V

48V

54V

Rated Current

40A

36A

28A

25A

20A

16.7A

14.3A

12.5A

11.2A

Rated Power

480W

540W

560W

600W

600W

601.2W

600.6W

600W

604.8W

Ripple & Noise (max.) Note 2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

250mVp-p

250mVp-p

250mVp-p

350mVp-p

Voltage Adj. Range

10.2 ~ 12.6V

12.7 ~ 15.8V

17 ~ 21V

20.4 ~ 25.2V

25.5 ~ 31.5V

30.6 ~ 37.8V

35.7 ~ 44.1V

40.8 ~ 50.4V

45.9 ~ 56.7V

Current Adj. Range

Can be adjusted by internal potentiometer

20 ~ 40A

18 ~ 36A

14 ~ 28A

12.5 ~ 25A

10 ~ 20A

8.3 ~ 16.7A

7.1 ~ 14.3A

6.2 ~ 12.5A

5.6 ~ 11.2A

Voltage Tolerance Note 3

±3.0%

±2.0%

±1.5%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation Note 5

±2.0%

±1.5%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup, Rise Time

500ms, 80ms at full load         230VAC/115VAC

Hold Up Time (typ.)

15ms at full load         230VAC/115VAC

Input:

Voltage Range

90~305VAC          127 ~ 431VDC

Frequency Range

47~63Hz

Power Factor (typ.)

PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load

Efficiency (Typ.)

 93%

94%

95%

95%

95.5%

95.5%

96%

96%

96%

AC Current (Typ.)

7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC

Inrush Current (Typ.)

COLD START 70A(twidth=1000us measured at 50% Ipeak) at 230VAC

Leakage Current

<0.75mA / 277VAC

Protection:

Overload

105 ~ 125%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Short Circuit

Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

13 ~ 16V

16.5 ~ 20.5V

22 ~ 26V

26 ~ 30V

32.5 ~ 36.5V

39.5 ~ 43.5V

46 ~ 50V

52.5 ~ 56.5V

59 ~ 63V

Protection type : Shut down and latch off o/p voltage, re-power on to recover

Over Temperature

Shut down and latch off o/p voltage, re-power on to recover

Function:

Remote On/Off Control

Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit

5V Standby

5VSB : 5V@0.5A ; tolerance±5%, ripple : 100mVp-p(max.)

Environment:

Working Temp.

-40 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 95% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 60°C)

Vibration

20 ~ 500Hz, 10G 12min. / 1cycle 72 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

UL60950-1, TUV EN60950-1 approved

Withstand Voltage

I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A

Others

MTBF

76.9Khrs min. MIL-HDBK-217F(25?)

Dimension

11 x 5.7 x 2 in (L*W*H)

Packing

8.6 lbs; 4pcs / 16.6Kg / 0.9CUFT

 

Electrical Specifications
Dimensions 11 x 5.7 x 2 in (L*W*H)
Number of Outputs 1
Output Voltage 12V
PDF Specs View Spec Sheet
Wattage 600
General
Industry Aliases new

HEP-600-12

  • Brand: Mean Well
  • Product Code: HEP-600-12
  • Availability: Call for Availability
  • $216.00

  • Ex Tax: $216.00

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.