Max Output Wattage (W) - 40 Watts

Output Voltage (VDC) - 42 Volts

Please read!!

Blank : IP67 rated. Cable for I/O connection.
A - Type : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B - Type : IP67 rated. Constant current level adjustable through output cable with 1 ~ 10Vdc or 10V PWM signal or resistance. 
D - Type : (option, saftey pending) : IP67 rated. Timer dimming function, contact Peak to Peak for details.

Model No. HLG-40H-42 HLG-40H-42A HLG-40H-42B HLG-40H-42D
Output:  DC Voltage 42V
Constant Current Region 25.2~42V
Rated Current 0.96A
Rated Power 40.32W
Ripple & Noise (max.) 200mVp-p
Voltage ADJ. Range 40 ~ 46V
Current Adj. Range Can be adjusted by internal potentiometer A type and C type only
0.58 ~ 0.96A
Voltage Tolerance ±1.0%
Line Regulation ±0.5%
Load Regulation ±0.5%
Setup, Rise Time 1500ms, 80ms/115VAC  at full load 230VAC/115VAC 1000ms 80ms/230VAC at full load
Hold up Time 16ms/230VAC  at full load 16ms/115VAC
Input: Voltage Range 90~305VAC 127~431VDC

Frequency Range

47~63Hz
Power Factor (Typ.) PF>0.98/115VAC, PF>0.95/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
Efficiency (Typ.) (230Vac) 88.5%
Efficiency (Typ.) (277Vac) 0%
AC Current (Typ.) 0.43A / 115VAC------0.24A / 230VAC-------0.23A / 277VAC
Inrush Current (Typ.) COLD START 50A (twidth=210µS measured at 50% lpeak) at 230VAC
Leakage Current <0.75mA / 277VAC
Protection: Over Current 95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Short Circuit Protection Hiccup mode, recovers automatically after fault condition is removed.
Over Voltage 48 ~ 58V
Protection type: Shut down and latch off o/p voltage, re-power on to recover
Over Temperature 85°C±10°C (RTH2)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
Environment: Working Temp. -40 ~ +70°C (Refer to "Derating Curve")
Working Humidity 20 ~ 95% RH non-condensing
Storage Temp., Humidity -40 ~ +80°C, 10 ~ 95% RH
Temp. Coefficient ±0.03%/°C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 5G 12min. / 1cycle, period for 72min. each along X, Y, Z axes
Safety & EMC Safety Standards UL8750, CSA C22.2 No. 250.0-08,  ( except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved design refer to UL60950-1, TUV EN60950-1, EN60335-1
Withstand Voltage I/P - O/P : 3.75KVAC-----I/P-FG : 2KVAC---- O/P-FG : 0.5KVAC
Isolation Resistance I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH
EMC Emission Compliance to EN55015, EN61000-3-2 Class C ( ≥60% load) ; EN61000-3-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 4KV), criteria A
Others: MTBF 336.5Khrs min. MIL-HDBK-217F (25°C)
Dimension 171 x 5 x 36.8mm (LxWxH)
Packing 0.73Kg; 20pcs / 16.6Kg / 0.9CUFT
Electrical Specifications
Dimensions 171 x 61.5 x 36.8
Input Voltage 90~305VAC
Number of Outputs 1
Output Voltage 42V