Key features for GSM06U06-P1J


Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over Temperature
Cooling by free air convection
LED indicator for power on
100% full load burn - in test
No load power consumption <0.5W
All using 105°C long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
GSM06U06-P1J Datasheet / Full Specs

GSM06U06-P1J

Double click on above image to view full picture

Zoom Out
Zoom In

More Views


extended warranty program

Product Details

Model No. GSM06U Series

Max Output Wattage (W) - 6 Watts

Output Voltage (VDC) – 5, 6, 7.5, 9, 12, 15, 18, 24 Volts

Model No.

 

GSM06U05-P1J

GSM06U06-P1J GSM06U07-P1J GSM06U09-P1J

GSM06U12-P1J

GSM06U15-P1J

GSM06U18-P1J

GSM06U24-P1J

Output: 

DC Voltage

5V

6V 7.5V 9V

12V

15V

18V

24V

Rated Current

1.2A

1.0A 0.8A 0.66A

0.5A

0.4A

0.33A

0.25A

Current Range

0 ~ 1.2A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.66A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.33A 0 ~ 0.25A

Rated Power

6W

6W 6W 6W

6W

6W

6W

6W

Ripple & Noise (max.) Note 2

50mVp-p

50mVp-p 80mVp-p 80mVp-p

100mVp-p

120mVp-p

150mVp-p

180mVp-p

Voltage Tolerance Note 3

±5.0%

±5.0% ±5.0% ±5.0%

±5.0%

±5.0%

±5.0%

±4.0%

Line Regulation Note 4

±0.5%

±0.5% ±0.5% ±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation Note 5

±5.0%

±5.0% ±5.0% ±5.0%

±3.0%

±3.0%

±3.0%

±2.0%

Setup, Rise, Hold Up Time

1000ms, 50ms, 12ms at full load

Input:

Voltage Range

80~264VAC         120~370VDC

Frequency Range

47~63Hz

Power Factor (typ.)

PF>0.91 / 230VAC PF>0.98 / 115VAC at full load

Efficiency (Typ.)

 68%

74% 74% 76%

77%

79%

80%

82%

AC Current (Typ.)

0.18A / 100VAC  

Inrush Current (Typ.)

30A / 230VAC

Leakage Current

Touch current <50μ A/264VAC

Protection:

Overload

>105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

>120% rated output voltage

Protection type : Clamp by zener diode

Environment:

Working Temp.

0 ~ +40?(Refer to "Derating Curve")

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.04%/°C (0 ~ 40°C)

Vibration

10 ~ 500Hz, 2G 10min. / 1cycle 60 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

ANSI/AAMI ES60601-1-11 approved

Withstand Voltage

I/P-O/P:5656VDC

Isolation Resistance

I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25? / 70% RH

EMC Emission

Compliance to FCC PART 15 CLASS B, FCC PART 18

Others

MTBF

500Khrs min. MIL-HDBK-217F(25?)

Dimension

1.26 x 2.6 x 1.7 in (L*W*H)

Packing

0.22 lbs; 110pcs / 12Kg /CARTON

Electrical Specifications

Name GSM06U06-P1J
SKU GSM06U06-P1J
Manufacturer Mean Well
Dimmable No
Wattage 6
Number of Outputs 1
Input Voltage No
Output Voltage No
Output Rated Current No
Dimensions 1.26 x 2.6 x 1.7 in (L*W*H)
Weight (Pounds) 0.2200

Product Tags