web statistics
  • GSM120A12-R7B


Mean Well Authorized Distributor since 1997

Model No. GSM120A Series

Max Output Wattage (W) - 120 Watts

Output Voltage (VDC) –12, 15, 20, 24, 48 Volts

Model No.

 

GSM120A12-P1J

GSM120A15-P1J

GSM120A20-P1J

GSM120A24-P1J

GSM120A48-P1J

Output: 

DC Voltage

12V

15V

19V

24V

48V

Rated Current

8.5A

7A

6A

5A

2.5A

Current Range

0 ~ 8.5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A

Rated Power

102W

105W

120W

120W

120W

Ripple & Noise (max.) Note 2

120mVp-p

150mVp-p

180mVp-p

200mVp-p

240mVp-p

Voltage Tolerance Note 3

±5.0%

±5.0%

±5.0%

±3.0%

±2.5%

Line Regulation Note 4

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Load Regulation Note 5

±5.0%

±5.0%

±5.0%

±3.0%

±2.5%

Setup, Rise Time

1500ms, 30ms/230VAC           2000ms,30ms/115VAC at full load

Hold Up Time (typ.)

20ms/230VAC           20ms/115VAC at full load

Input:

Voltage Range

80~264VAC

Frequency Range

47~63Hz

Power Factor (typ.)

PF>0.93 / 230VAC        PF>0.97 / 115VAC at full load

Efficiency (Typ.)

 88%

89%

89%

90%

91%

AC Current (Typ.)

1.4A / 115VAC      0.7A / 230VAC

Inrush Current (Typ.)

35A / 230VAC         70A / 115VAC

Leakage Current

Earth leakage current < 100μ A/264VAC , Touch current <100μ A/264VAC

Protection:

Overload

105 ~ 160% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

105 ~ 135% rated output power

Protection type : Shut down o/p voltage, re-power on to recover

Over Temperature

Shut down o/p voltage, re-power on to recover

Environment:

Working Temp.

-30 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 40°C)

Vibration

10 ~ 500Hz, 2G 10min. / 1cycle 60 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

ANSI/AAMI ES60601-1, TUV EN60601-1 approved

Isolation Level

Primary-Secondary: 2xMOPP

Withstand Voltage

I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25? / 70% RH

EMC Emission

Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3, FCC PART 15 class B

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A

Others

MTBF

372Khrs min. MIL-HDBK-217F(25?)

Dimension

6.5 x 2.6 x 1.4 in (L*W*H)

Packing

1.3 lbs; 20pcs / 13Kg /0.9CUFT

Electrical Specifications
Dimensions 6.5 x 2.6 x 1.4 in (L*W*H)
Number of Outputs 1
Output Voltage 12V
PDF Specs View Spec Sheet
Wattage 120
General
Industry Aliases new

GSM120A12-R7B

  • Brand: Mean Well
  • Product Code: GSM120A12-R7B
  • Availability: Call for Availability
  • $43.20

  • Ex Tax: $43.20

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.