web statistics
  • RSD-200C-48 Mean Well Railway Single Output DC-DC Converter

Model No. - RSD-200C-48

Max Output Wattage (W) - 200 Watts

Output Voltage (VDC) - 48 Volts

Model No. RSD-200B-12 RSD-200B-48 RSD-200B-48 RSD-200C-12 RSD-200C-24 RSD-200C-48 RSD-200D-12 RSD-200D-24 RSD-200D-48
Output:  DC Voltage 12V 24V 48V 12V 24V 48V 12V 24V 48V
Current Range 0~16.7A 0~8.4A 0~4.2A 0~16.7A 0~8.4A 0~4.2A 0~16.7A 0~8.4A 0~4.2A
Rated Current 16.7A 8.4A 4.2A 16.7A 8.4A 4.2A 16.7A 8.4A 4.2A
Rated Power 200.4W 201.6W 201.6W 200.4W 201.6W 201.6W 200.4W 201.6W 201.6W
Ripple & Noise (max.) 120mVp-p 150mVp-p 180mVp-p 120mVp-p 150mVp-p 180mVp-p 120mVp-p 150mVp-p 180mVp-p
Voltage Tolerance ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
Line Regulation ±0.2% ±0.2% ±0.5% ±0.2% ±0.2% ±0.5% ±0.2% ±0.2% ±0.5%
Load Regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Setup, Rise Time 800ms, 50ms at full load
Hold up Time B/C- type complies with S1 level @ full load, comply with S2 level @ 70% load ; D-type complies with S2 level @ full load
Input: Voltage Range Continuous 16.8 ~ 31.2 VDC 33.6 ~ 62.4 VDC 67.2 ~ 143 VDC
Voltage Range 1 sec. 14.4 ~ 33.6 VDC 28.8 ~ 67.2 VDC 57.6 ~ 154 VDC
Efficiency (Typ.) 89% 89% 89% 91% 91% 91% 91% 91% 91%
DC Current (Typ.) 9.6A / 24V 9.6A / 24V 9.6A / 24V 4.8A / 48V 4.8A / 48V 4.8A / 48V 2.1A / 110V 2.1A / 110V 2.1A / 110V
Inrush Current (Typ.) 45A / 24VDC 45A / 48VDC 45A / 110VDC
Protection: Overload 105 ~ 135%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temperature 90°C±5°C (TSW1) detect on main power transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Environment: Working Temp. -40 ~ +55°C (no derating) ; +70°C @60% load by free air convection ; +70°C no derating with external base plate, TX class compliance
Working Humidity 5 ~ 95% RH non-condensing
Storage Temp., Humidity -40 ~ +85°C, 5 ~ 95% RH
Temp. Coefficient ±0.03%/°C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Safety & EMC Safety Standards Meet IEC60950-1 (LVD)
Withstand Voltage I/P - O/P : 4KVAC I/P-FG : 2.5KVDC O/P-FG : 2.5KVDC
Isolation Resistance I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH
EMC Emission Compliance to EN55022 (CISPR22), Conduction Emission: Class A, Radiation Emission: Class B
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8 ; light industry level, criteria A
Railway Standard Meet EN60155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
Others: MTBF 218.2Khrs min. MIL-HDBK-217F (25°C)
Dimension 191 x 86 x 40mm (LxWxH)
Packing 0.94Kg; 12pcs / 12.3Kg / 0.8CUFT
Electrical Specifications
Dimensions 191 x 86 x 40mm (L x W x H)
Number of Outputs 1
Output Voltage 48V
PDF Specs View Spec Sheet
Wattage 108
General
Industry Aliases new

RSD-200C-48 Mean Well Railway Single Output DC-DC Converter

  • Brand: Mean Well
  • Product Code: RSD-200C-48
  • Availability: Call for Availability
  • $113.63

  • Ex Tax: $113.63

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.