Model No. - LPF-16D-54
Max Output Wattage (W) - 16 Watts
Output Voltage (VDC) - 54 Volts
Model No. | LPF-16D-12 | LPF-16D-15 | LPF-16D-20 | LPF-16D-24 | LPF-16D-30 | LPF-16D-36 | LPF-16D-42 | LPF-16D-48 | LPF-16D-54 | |
Output: | DC Voltage | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
Constant Current Region | 6.6~12V | 8.25~15V | 11~20V | 13.2~24V | 16.5~30V | 19.8~36V | 23.1~42V | 26.4~48V | 29.7~54V | |
Rated Current | 1.34A | 1.07A | 0.8A | 0.67A | 0.54A | 0.45A | 0.39A | 0.34 | 0.3A | |
Rated Power | 16.08W | 16.05W | 16W | 16.08W | 16.2W | 16.2W | 16.38W | 16.32W | 16.2W | |
Ripple & Noise (max.) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
Voltage Tolerance | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup, Rise Time | 1500ms, 80ms / 115VAC at full load ---- 1500ms, 80mas / 230VAC | |||||||||
Hold up Time | 16ms/230VAC - - -16ms/115VAC at full load | |||||||||
Input: | Voltage Range | 90~305VAC 127~431VDC | ||||||||
Frequency Range |
47~63Hz | |||||||||
Power Factor (Typ.) | PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||||||
Efficiency (Typ.) | 84% | 84% | 86% | 86% | 86% | 86% | 86% | 86% | 86% | |
AC Current (Typ.) | 0.4A / 115VAC------0.25A / 230VAC--------0.2A / 277VAC | |||||||||
Inrush Current (Typ.) | COLD START 45A (twidth=200µS measured at 50% lpeak) at 230VAC | |||||||||
Leakage Current | <0.75mA / 240VAC | |||||||||
Protection: | Over Current | 95 ~ 108% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
Short Circuit Protection | Hiccup mode, recovers automatically after fault condition is removed. | |||||||||
Over Voltage | 15~18V | 17.5~21V | 23~27V | 28~35V | 34~40V | 41~49V | 46~54V | 54~63V | 59~66V | |
Protection type: Shut down and latch off o/p voltage, re-power on to recover | ||||||||||
Over Temperature | 100°C±5°C (TSW1) Detect on U2 | |||||||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||
Environment: | Working Temp. | -35 ~ +70°C (Refer to "Derating Curve") | ||||||||
Working Humidity | 20 ~ 95% RH non-condensing | |||||||||
Storage Temp., Humidity | -40 ~ +80°C, 10 ~ 95% RH | |||||||||
Temp. Coefficient | ±0.03%/°C (0 ~ 50°C) | |||||||||
Vibration | 10 ~ 500Hz, 2G 12min. / 1cycle, period for 72min. each along X, Y, Z axes | |||||||||
Safety & EMC | Safety Standards | UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, EN62384, J61347-1, J61347-2-13 approved, IP67(optional), ; Design refer to UL60950-1, TUV EN60950-1 | ||||||||
Withstand Voltage | I/P - O/P : 3.75KVAC | |||||||||
Isolation Resistance | I/P - O/P : 100M Ohms / 500VDC / 25°C / 70% RH | |||||||||
EMC Emission | Compliance to EN55015, En61000-3-2 Class C ( ≥50% load) ; EN61000-3-3 | |||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A | |||||||||
Others: | MTBF | 473.3Khrs min. MIL-HDBK-217F (25°C) | ||||||||
Dimension | 148 x 40 x 32mm (LxWxH) | |||||||||
Packing | 0.21Kg; 40pcs / 9.4Kg / 1.02CUFT |
Electrical Specifications | |
Dimensions | 148 x 40 x 32 |
Input Voltage | 90~305VAC |
Model Type | D-Type |
Number of Outputs | 1 |
Output Voltage | 54V |
PDF Specs | View Spec Sheet |
Wattage | 16 |
General | |
Dimmable | Built-in 3-in-1 PWM signal dimming |
Industry Aliases | new |
LPF-16D-54 Mean Well LED Power Supply
- Brand: Mean Well
- Product Code: LPF-16D-54
- Availability: Call for Availability
-
$20.70