You have no items in your shopping cart.
Product Details
AC input voltage range: 90-264VAC; 127-370VDC
AC inrush current: Cold start, 35A at 115VAC, 60A at 230VAC
DC adjustment range: CH1: -5-+10% rated output voltage
Overload protection: 110-160% hiccup mode, auto recovery
Over voltage protection: CH1: 115%-140% rated output voltage
Withstand voltage: I/P-O/P: 4KVAC, I/P-FG: 1.5KVAC, 1 minute
Working temperature: -20°C to 70°C (refer to output derating curve)
AC inrush current: Cold start, 35A at 115VAC, 60A at 230VAC
DC adjustment range: CH1: -5-+10% rated output voltage
Overload protection: 110-160% hiccup mode, auto recovery
Over voltage protection: CH1: 115%-140% rated output voltage
Withstand voltage: I/P-O/P: 4KVAC, I/P-FG: 1.5KVAC, 1 minute
Working temperature: -20°C to 70°C (refer to output derating curve)
Electrical Specifications
| Features | Universal AC input/Full Range PF>0.95@230VAC (200W) Protections: Short Circuit/Overload/Over voltage/OTP (200W) Leakage currents<180uA Built-in remote sense and remote ON/OFF control (200W) PG/PF signal output (optional for 120W) 80W/140W free air convection, 120W/200W with 25CFM forced air 100% full load burn-in test 3 years warranty Suitable for medical & IT applications |
| Dimensions | 177.8 x 108 x 35.5 mm |
| Weight (Pounds) | 1.2000 |
| Manufacturer | Mean Well |
| Wattage | 120 |
| Input Voltage | 90 ~ 264 VAC Universal |
| Number of Outputs | 1 |
| Output Voltage | 15V |