  • NPF-60D-15


Mean Well Authorized Distributor since 1997

Model No. - NPF-60D Series

Max Output Wattage (W) - 60 Watts

Output Voltage (VDC)12, 15, 20, 24, 30, 36, 42, 48, 54 Volts

Model No.

NPF-60D-12

NPF-60D-15

NPF-60D-20

NPF-60D-24

NPF-60D-30

NPF-60D-36

NPF-60D-42

NPF-60D-48 NPF-60D-54

Output: 

DC Voltage

12V

15V

20V

24V

30V

36V

42V

48V 54V

Rated Current

5A

4A

3A

2.5A

2A

1.67A

1.43A

1.25A 1.12A

Constant Current Range

7.2 ~ 12A

9 ~ 15A

12 ~ 20A

14.4 ~ 24A

18 ~ 30A

21.6 ~ 36A

25.2 ~ 42A

28.8 ~ 48V 32.4 ~ 54V

Rated Power

60W

60W

60W

60W

60W

60.12W

60.06W

60W 60.48W

Ripple & Noise (max.) Note 2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p 350mVp-p

Voltage Tolerance Note 3

±4.0%

±4.0%

±4.0%

±3.0%

±3.0%

±2.0%

±1.0%

±1.0% ±1.0%

Line Regulation Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5% ±0.5%

Load Regulation Note 5

±1.5%

±1.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5% ±0.5%

Setup, Rise Time

500ms, 80ms at 95% load        115VAC / 230VAC

Hold up Time

16ms / 230VAC        16ms/115VAC at full load

Input:

Voltage Range

 90 ~ 305VAC     127~431VDC

Frequency Range

47~63Hz

Power Factor (typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characterisitc" curve)
Total Harmonic Distortion THD< 20% when output loading?60% at 115VAC/230VAC input and output loading? 75% at 277VAC input

Efficiency (Typ.)

86%

87%

88%

89%

90%

90%

90%

90% 90%

AC Current (Typ.)

0.8A/115VAC               0.4A/230VAC             0.32A/277VAC

Inrush Current (Typ.)

COLD START 50A(twidth= 270μs measured at 50% lpeak) at 230VAC

MAX. No. of PSUs on 16A Circuit Breaker 9 units (circuit breaker of type B)/ 16 units (circuit breaker of type C) at 230VAC

Leakage Current

<0.25mA / 277VAC

Protection:

Over Current

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

15 ~ 17V

17.5 ~ 21V

23 ~ 27V

28 ~ 34V

34 ~ 40V

41 ~ 46V

46 ~ 54V

54 ~ 60V 59 ~ 66V

Protection type: Shut down o/p voltage, re-power on to recover

 

Environment:

Working Temp.

-40 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 95% RH non-condensing

Storage Temp., Humidity

-40 ~ +80°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 50°C)

Vibration

10 ~ 500Hz, 5G 12min. / 1 cycle 72 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN60335-1

Withstand Voltage

I/P-O/P:3.75KVAC

Isolation Resistance

I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Compliance to EN55015, EN61000-3-2 Class C (?60% load) ; EN61000-3-3

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A

Others:

MTBF

314.05Khrs min.    MIL-HDBK-217F (25°C)

Dimension

150*53*35mm (L*W*H)

Packing

0.49Kg; 30pcs / 15.7Kg / 1.0CUFT

Electrical Specifications
Dimensions 6.0 x 2.1 x 1.4 in (L*W*H)
Input Voltage 90~305VAC
Number of Outputs 1
Output Voltage 15V
PDF Specs View Spec Sheet
Wattage 60
General
Industry Aliases new

NPF-60D-15

  • Brand: Mean Well
  • Product Code: NPF-60D-15
  • Availability: Call for Availability
  • $27.90

  • Ex Tax: $27.90

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.