You have no items in your shopping cart.
Product Details
AC input voltage range: 90-264VAC; 120-370VDC
AC inrush current: Cold start, 15A at 115VAC, 30A at 230VAC
DC Adjustment range: CHI1: -5-+10% rated output voltage
Overload protection: 53-75W hiccup mode, auto recovery
Over voltage protection: CHI1: 115%-135% rated output voltage
Withstand voltage: I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, 1 minute
Working temperature: -10°C to +60°C (refer to output derating curve)
AC inrush current: Cold start, 15A at 115VAC, 30A at 230VAC
DC Adjustment range: CHI1: -5-+10% rated output voltage
Overload protection: 53-75W hiccup mode, auto recovery
Over voltage protection: CHI1: 115%-135% rated output voltage
Withstand voltage: I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, 1 minute
Working temperature: -10°C to +60°C (refer to output derating curve)
Electrical Specifications
| Features | Universal AC input/Full Range Protections: Short Circuit/Overload/Over voltage Cooling by free air convection Low leakage current <0.5mA 100% full load burn-in test Low cost, high reliability 2 years warranty |
| Dimensions | 127x 76x 28mm |
| Weight (Pounds) | 0.4000 |
| Manufacturer | Mean Well |
| Wattage | 45 |
| Input Voltage | 90 ~ 264 VAC Universal |
| Number of Outputs | 1 |
| Output Voltage | 15V |