web statistics
  • RST-5000-24


Mean Well Authorized Distributor since 1997

Model No. - RST-5000 Series

Max Output Wattage (W) - 5000 Watts

Output Voltage (VDC) – 24, 36, 48 Volts

Model No.

RST-5000-24

RST-5000-36

RST-5000-48

Output: 

DC Voltage

24V

36V

48V

Rated Current

200A

138A

105A

Current Range

0 ~ 200A

0 ~ 138A

0 ~ 105A

Rated Power

4800W

4968W

5040W

Ripple & Noise (max.) Note 2

150mVp-p

200mVp-p

200mVp-p

Voltage ADJ. Range

23.5 ~ 28.8V

35 ~ 43.2V

47 ~ 57.6V

Can be adjusted via built-in potentiometer

Voltage Tolerance Note 3

±1.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

Load Regulation

±0.5%

±0.5%

±0.5%

Setup, Rise Time

2200ms, 80ms/230VAC at full load

Hold up Time (Typ.)

20ms / 230VAC at 75% load       14ms/115VAC at full load

Input:

Voltage Range

3ψ3-wire /?196 ~ 305VAC or 3ψ4-wire / Y 340 ~ 530VAC

Frequency Range

47~63Hz

Power Factor (Typ.)

0.95/230VAC(400VAC) at full load

Efficiency (Typ.)

89%

90%

91%

AC Current (Typ.)

15A/230VAC(3ψ3-wire /?) 9A/400VAC(3ψ4-wire / Y)

Inrush Current (Typ.)

75A/230VAC(3ψ3-wire /?) 50A/400VAC(3ψ4-wire / Y)

Leakage Current

<3.5mA /?305VAC(Y 530VAC)

Protection:

Overload

100 ~ 112% rated output power

User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover

Over Voltage

30 ~ 33.6V

45 ~ 50.4V

60 ~ 67.2V

Protection type: Shut down o/p voltage, re-power on to recover

Over Temperature

Shut down o/p voltage, recovers automatically after temperature goes down

Function: Remote Sense Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual
Current Sharing Up to 20000W or (3+1) units. Please refer to the Function Manual.
Output Voltage Programmable Adjustment of output voltage is allowable to between 20 ~ 120% of nominal output voltage. Please refer to the Function Manual
Constant Current Level Programmable Adjustment of constant current level is allowable to between 20 ~ 100% of rated current. Please refer to the Function Manual.
Auxiliary Power (AUX) 12V@0.1A(Only for Remote ON-OFF control)
Remote On-Off Control Please refer to the Function Manual.
Alarm Signal Output AC fail, DC OK, fan fail, OTP. Please refer to the Function Manual.

Environment:

Working Temp.

-30 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 50°C)

Vibration

10 ~ 500Hz, 2G 10min. / 1cycle 60 min. each along X, Y, Z axes

Safety & EMC

(Note 5)

Safety Standards

UL60950-1, TUV EN60950-1 approved

Withstand Voltage

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Parameter

Standard

Test Level / Note

Conducted

EN55022 (CISPR22) / EN55011 (CISPR11)

Class A

Radiated

EN55022 (CISPR22) / EN55011 (CISPR11

Class A

Harmonic Current

EN61000-3-2

-----

Voltage Flicker

EN61000-3-3

-----

EMC Immunity

EN55024 , EN61204-3, EN61000-6-2

Parameter

Standard

Test Level / Note

ESD

EN61000-4-2

Level 3, 8KV air ; Level 2, 4KV contact

Radiated

EN61000-4-3

Level 3

EFT / Burst

EN61000-4-4

Level 3

Surge

EN61000-4-5

Level 4, 2KV/Line-Line 4KV/Line-Earth

Conducted

EN61000-4-6

Level 3

Magnetic Field

EN61000-4-8

Level 4

Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods

Others:

MTBF

44.1K hrs min. Telcordia SR-332 (Bellcore) ; 34.6K hrs min. MIL-HDBK-217F (25?)

Dimension

18 x 8.3 x 3.3 in (L*W*H)

Packing

22lbs; 1pcs / 10.1Kg / 1.15CUFT

Electrical Specifications
Dimensions 18 x 8.3 x 3.3 in (L*W*H)
Number of Outputs 1
Output Voltage 24V
PDF Specs View Spec Sheet
General
Industry Aliases new

RST-5000-24

  • Brand: Mean Well
  • Product Code: RST-5000-24
  • Availability: Call for Availability
  • $1,044.00

  • Ex Tax: $1,044.00

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.